Detailed Notes on Dp50rb
Detailed Notes on Dp50rb
Blog Article
one.2.two Warning Labels Warning Labels Which means Make sure you meticulously read this handbook in advance of use system. The following labels really are a. Will not location the machine with a sloped surface area. Otherwise the out there if the method gadget may perhaps slide, resulting in own injuries or perhaps the machine functions Using the cell malfunction.
The person just isn't allowed to open the addresses and panel with the program, neither NOTE: product disassemble is permitted. To make sure the system functionality and safety, only Mindray engineers or engineers authorized by Mindray can complete maintenance.
Get an entire and extended check out from the anatomical structure by panoramic imaging coupled with velocity indication and forward/backward scan ability generating scanning easier, smoother plus much more controllable.
This handbook may well referring to data protected by copyright or patents and won't convey any license under the patent rights or copyright of Mindray, or of Other individuals. Site 9: Assertion
Slash off cable ties connecting the key unit over the Display screen by diagonal cutting pliers, then pull out the corresponding cable plugs.
After you end the scanning and also the graphic capture, it is best to electrical power from the program and disconnect the system from your AC energy source, then pull out AC electric power cables. Webpage 109: Battery Connecting Board
The chapter provides the method to confirm major functionality and functionality of merchandise. This is often only used for reference, not preventive execution. Operate examining and screening of the aspect shall be carried out by Mindray company engineers and also the person jointly. Webpage 66: Normal Test
Uncover far better diagnostic information by prolonged check out with the anatomical composition on all convex probes.
Analyzing sufferers in right now’s demanding atmosphere needs modern technological innovation that enables clinicians to produce swift and confident diagnoses. The flexibility from the DP-50 expands your scientific utility although assisting to improve patient care.
five.two.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy Check Action: Do changes as the way in which in testing the utmost depth. Report the gap by 20mm Every section to the longitudinal targets line using the measurement caliper; Select the value with the greatest mistake (to 20mm), estimate the precision using the formulation beneath The measurement caliper should be positioned with the higher fringe of the goal, Be aware:... Page 79 Transverse geometric positioning accuracy Examination Stage: Include the scan surface area on the phantom with drinking water or couple gel, gently Call the probe Along with the scan surface Modify the depth, generating the transverse targets being displayed inside the impression. Regulate the focus stage to become posited beside the transverse targets (the common is just not clear) Alter parameters like get, TGC, producing Every single transverse targets being Plainly exhibited. Webpage 80 five.five.2.4 Blackout Area Exam Action: Cover the scan surface from the phantom with water or pair gel, Carefully Get hold of the probe Using the scan surface area Modify the depth in a reduce benefit, and set the focus at the nearest place to the scan surface. Minimize the value of parameters like AP, Gain till the qualifications sound just can be witnessed. Page 81: Computer software Improve And Routine maintenance
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
.. Site 161 The indicator within the printer Faults manifest in the event the adapter turns orange, as well as printing printer adapter runs. Disconnect and hook up the fails. power adapter, electrical power to the printer adapter all over again, and verify whether or not the printing is regular just after 1 moment. Page 163: Electrical Protection Inspection
Performance Exam 5.five.one Exam Course of action Resolution Detection depth Geometric Posture Precision Blackout place examination History Dp50rb login the Examination visuals 5.five.two Check Material The image used here is just for reference, stick to the graphic outcome in the true Notice: condition. Specifications: Show: set the contrast and brightness at the scientific software value (or the default position) Operation atmosphere: dim area, simulating the clinical software natural environment. Webpage 76 In issue the transverse resolution testing targets are horizontally shown, report the negligible distance of two targets that could be clearly recognized. Repeat the Procedure earlier mentioned for the transverse resolution screening targets at other depths. As proven in figure under. Axial resolution ... Website page 77 When utilizing the convex probe, retain the transverse resolution screening targets to notice: be displayed near the midline. When employing a linear probe with steer function, will not turn on the steer function when perform the transverse resolution test. Zoom from the area where by the targets located if essential. The diameter with the concentrate on level at a certain depth is equivalent to your transverse resolution with the depth. Site seventy eight five.
Your Instrument for deeper biopsy: allowing changes towards the scan line to get far better visibility in the needle, nerves and modest vessels, guaranteeing the continuity of all facts.